PLEASE NOTE – WE WILL BE CLOSED FROM FRIDAY 18TH OCTOBER UNTIL SUNDAY 27TH OCTOBER. ANY ORDERS PLACED DURING THIS TIME WON’T START TO BE DISPATCHED UNTIL WE RE-OPEN ON MONDAY 28TH OCTOBER. THANK YOU.

Wired Campers Limited Victron Filax 2 16A 230V/50Hz Automatic Mains Transfer Switch
Wired Campers Limited Victron Filax 2 16A 230V/50Hz Automatic Mains Transfer Switch

Victron Energy Filax 2 16A 230V/50Hz Automatic Mains Transfer Switch

Regular price £219.99
Unit price  per 
Tax included.

The Victron Filax 2 has been designed to switch critical or sensitive loads, such as computers, industrial controls or modern entertainment equipment from one AC source to another.

The priority source typically is the mains, a generator or shore power. The alternate source typically is an inverter.

With its switching time of less than 20 milliseconds sensitive loads will continue to operate without disruption.

The Filax is not intended to supply high power household equipment like washing machines, or electric motors.
  • The Filax is an open transition (break before make) transfer switch.
  • The maximum load transfer time is 16ms.
The load is normally supplied by the priority source, and is transferred to the alternate source if:
  • The voltage of the priority source drops below the threshold value.
  • The frequency of the priority source drops below the low frequency threshold value, or increases beyond the high frequency threshold value.
  • Reverse transfer from the alternate source to the priority source is initiated when the priority source has operated within the voltage and frequency reverse switching limits during 30s.
TECHNICAL SPECIFICATION
  • Maximum current - 16A
  • Priority source: low voltage switching threshold - 180V
  • Priority source: low voltage reverse switching threshold - 188V
  • Priority source: low frequency switching threshold - 45Hz
  • Priority source: low frequency reverse switching threshold - 47Hz
  • Priority source: high frequency switching threshold - 60Hzz
  • Priority source: high frequency reverse switching threshold - 56Hz
  • Priority source: maximum continuous input voltage - 260V
  • Alternate source: maximum continuous input voltage - 260V
  • Maximum load transfer time and reverse transfer time - 16ms
  • Reverse switching delay (seconds) - 30s
  • Operating temperature range - -20 to +50°C
  • Humidity (non-condensing) - Max 95%